Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Main subject
Year range
1.
Arch. argent. pediatr ; 121(5): e202202908, oct. 2023. tab
Article in English, Spanish | LILACS, BINACIS | ID: biblio-1509498

ABSTRACT

Introducción. La pandemia por COVID-19 ha puesto de manifiesto la necesidad de pruebas diagnósticas rápidas. La prueba de referencia es la reacción en cadena de la polimerasa en tiempo real (RT-PCR). Requiere un equipo y personal capacitado, y su resultado puede llevar un tiempo de espera prolongado. El sistema BD Veritor® es el método rápido cromatográfico utilizado para la detección del antígeno del coronavirus de tipo 2 del síndrome respiratorio agudo grave, en individuos sintomáticos. El objetivo primario del siguiente trabajo es evaluar sensibilidad y especificidad del test de antígeno (TA) comparadas con la RT-PCR en población pediátrica. Población y métodos. Estudio prospectivo, de prueba diagnóstica. Se incluyó a todo menor de 17 años en los primeros 5 días de inicio de síntomas, que consultó desde julio de 2021 hasta febrero de 2022. Se calculó un mínimo de 300 muestras para lograr una precisión de ± 8,76 % y de ± 3,68 % para sensibilidad y especificidad respectivamente. Se analizaron en paralelo las muestras por ambas metodologías. Resultados. De 316 muestras pareadas, 33 fueron positivas por ambos métodos; 6 fueron positivas solo por RT-PCR. La especificidad del TA fue del 100 %; la sensibilidad, del 84,6 %, con un valor predictivo positivo y negativo del 100 % y del 98 % respectivamente. Conclusiones. El TA demostró ser útil en el diagnóstico de pacientes pediátricos con COVID-19 en los primeros 5 días de inicio de síntomas, aunque aquellos con TA negativo y alta sospecha clínica deberían confirmar su resultado con la RT-PCR.


Introduction. The COVID-19 pandemic has brought to light the need for rapid diagnostic tests. The gold standard test is reverse transcription-polymerase chain reaction (RT-PCR). RT-PCR requires equipment and trained personnel, and results may take a long waiting time. The BD Veritor® System is a rapid chromatographic method used for the detection of severe acute respiratory syndrome coronavirus 2 antigen in symptomatic individuals. The primary objective of this study is to assess the sensitivity and specificity of the antigen test (AT) compared to the RT-PCR in the pediatric population. Population and methods. Prospective study with a diagnostic test. All children younger than 17 years in the first 5 days of symptom onset, who consulted between July 2021 and February 2022, were included. A minimum of 300 specimens was estimated to achieve an accuracy of ±8.76% and ±3.68% for sensitivity and specificity, respectively. Specimens were analyzed in parallel using both methodologies. Results. Of 316 paired samples, 33 were positive by both methods; 6 were positive only by RT-PCR. The specificity of the AT was 100%; sensitivity was 84.6%, with a positive and negative predictive value of 100% and 98%, respectively. Conclusions. The AT proved to be useful in the diagnosis of pediatric patients with COVID-19 in the first 5 days of symptom onset, although those with a negative AT and high clinical suspicion should confirm their result with a RT-PCR.


Subject(s)
Humans , Infant, Newborn , Infant , Child, Preschool , Child , Adolescent , COVID-19/diagnosis , Prospective Studies , Sensitivity and Specificity , Reverse Transcriptase Polymerase Chain Reaction , Reverse Transcription , Pandemics , COVID-19 Testing , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL